4~2mA temperature Humidity Sensor

4~2mA temperature Humidity Sensor

FOB Price:
US 34-40 / Piece
Min.Order Quantity:
50 Piece/Pieces
Supply Ability:
1000 Piece/Pieces per Month
Port:
Shanghai
Place of Origin:
Shanghai, China (Mainland)
Payment Terms:
L/C,T/T,Western Union
Brand:
CH-BA
Products Model:
HT-5U-D
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: CH-BA

    Model Number: HT-5U-D

    Place of Origin: Shanghai, China (Mainland)

  • Usage: Outdoor

    Theory: Temperature Sensor

    Accuracy: 0.5%

  • Temperature range: 0-50

Packaging & Delivery

  • Packaging Details: normal
  • Delivery Detail: Shipped in 7 days after payment

Specifications

Features    

·          Humidity measurement for air ducts

·          Simple and secure installation

·          0-10V or 4-20mA measuring signals

·          Compact size and modern design

Applications

·          On return air ducts to measure return air humidity

·          On supply air ducts to measure supply air humidity

·          On fresh air ducts to measure outdoor air humidity.

Humidity Tansmitter

The transmitter measures the humidity by the honeywell humidity sensor HIH-3610. The transmitter analog output may be be 0-10V or 4-20mA. And the transmitter include a noise filter.the power suply is large range VDC18V----VDC30V.The humidity transmitter measurement range is 5%-95%.

  Ordering

Ordering number:RH-5I-D or RH-5I-D-T

-5 indicates the humidity transmitter accuracy is 5%; -3 indicates 3%, -2 indicates 2%.

-I  indicates the humiditt transmitter signal out is 4-20mA. If U indicates the signal is 0-10V.

-T indicates the humidity transmitter integration with temperature signal out.

For example:RH-5I-D-T

The duct humidity transmitter signal out is 4-20mA and the temperature signal out is 4-20mA.

Installation

Duct probes should be installed directly on the duct, in an area where the air stream is well mixed:

·          Locate a supply air sensor two or three meters down stream from the nearest fan and coil.

·          Mount the return air sensor close to the air inlet but downstream from a return fan if one is present.

·          To install the sensor, assemble base plate and probe, then drill a 12 mm hole and two 3 mm holes on a diameter of 25 mm in the duct.

·          Use two self-tapping sheet metal screws to tighten the mounting circuit in the cover.

·          Connect the wires according to the wiring diagram to the measuring circuit in the cover:

o         Only the humidity transmitter signal out  need three terminal connections,DC24V,Ground and humidity signal out.

o         If humidity and temperature transmitter signal out need for terminal connections,DC24V,Ground,humidity signal out and temperature signal out.

o         The connection signal cable should be shield wires.

·          Assemble the cover with the mounting plate.

·          Insert the assembled probe through the center opening of the mounting plate into the air stream.

·          Tighten the horizontal screw on the mounting plate to fix the probe to the duct.


 

Technical Specification

Power suply

Option voltage

VDC18V---VDC30V

Power Cunsumption

Max 2 VA

Signal out

signal

4-20mA

accuracy

5%

Humudity range

0%-100%

Sensing element

Capacitive Element:

Range

Accuracy

 

5%---95%

±0.3k

Connection

Connection Terminals

2.5 mm2

Environment

Operation
Climatic Conditions
Temperature
Humidity

To IEC 721-3-3
class 3 K5
-4070°C
<95% r.h.

Transport & Storage
Climatic Conditions
Temperature
Humidity
Mechanical Conditions

To IEC 721-3-2 and IEC 721-3-1
class 3 K3 and class 1 K3
-4080°C
<95% r.h.
class 2M2

Standards

          conform according to
EMC Standard 89/336/EEC
EMEI Standard 73/23/EEC


EN 61 000-6-1/ EN 61 000-6-3

 

Automatic electrical controls for household and similar use

Special requirement on temperature dependent controls

EN 60 730 1

 

EN 60 730 2 - 9

Pollution Class

Normal acc. To EN 60 730,RoHS compliant

Degree of Protection

IP56 to EN 60 529

 

Safety Class

III (IEC 60536)

Housing Materials

       Cover & Mounting Plate

Fire proof ABS plastic

General

Dimensions [mm]

Cover: 42 x 112 x 88 (H x W x D)

probe: ø 10 x 200 (Diameter x L)

Weight (including package)

135g

 

 
  • Email to this supplier
  • To :
    Kitty Weng  |  Shanghai huikong Energy Source Co., Ltd
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Shanghai huikong Energy Source Co., Ltd Bussiness Type:  Manufacturer
Scale:  11 - 50 People
Country/Region:  China (Mainland)/Asia
Established:  
You May Like:
Duct Temperature Sensor 4-20mA

Indoor temperature and humidity sensor

Duct Temperature Sensors 0-10V

Duct Temperature Sensors PT100

Room Temperature Sensor RTD PT100

Duct humidity temperature indicator

Duct Humidity Temperature Measurment outdoor

Immersion Temperature Sensor

Indoor humidity temperature measurement

NTC 10K Air Conditioner Temperature Sensor